Housing
Housing made of glass fibre reinforced technopolymer, self-extinguishing. Versions with integrated cable 4 x 0.22 mm2 or 6 x 0.25 mm2, length 2 m, other lengths 0.5 m … 10 m on request
Versions with integrated M8 connector
Versions with 0.1 m cable length and M12 connector, other lengths from 0.1 … 3 m on request
Protection degree: IP67 acc. to EN 60529
IP69K acc. to ISO 20653
(Protect the cables from direct high-pressure and high-temperature jets)
Main features
⦁ Actuation without mechanical contact
⦁ Output contacts: 2NC, 1NO+2NC or 1NO+1NC
⦁ Insensitive to dirt
⦁ Protection degrees IP67 and IP69K
⦁ Coded actuator
⦁ Technopolymer housing
⦁ Versions with M8 or M12 connector
Quality marks:
UL approval: E131787
TÜV SÜD approval: Z10 15 08 75157 008
EAC approval: RU C-IT.AД35.В.00454
Compliance with the requirements of: Low Voltage Directive 2014/35/EU Machinery Directive 2006/42/EC
EMC Directive 2014/30/EU.
General data
For safety applications up to: SIL 3 acc. to EN 62061
PL e acc. to EN ISO 13849-1
Interlock, no contact, coded: type 4 acc. to EN ISO 14119
Coding level: low acc. to EN ISO 14119
Safety parameter B10d: 20,000,000 (with compatible Pizzato Elettrica safety modules)
400,000
(at max. load: DC12 24 V 250 mA)
Service life: 20 years
Ambient temperature: -25°C … +80°C Ambient temperature with flexible installation cable: -5°C … +80°C
Vibration resistance: 10 gn (10 … 150 Hz) acc. to
IEC 60068-2-6
Shock resistance: 30 gn; 11 ms acc. to EN 60068-2-27
Pollution degree 3
Screw tightening torque: 0.8 … 2 Nm
In compliance with standards:
IEC 60947-1, EN 60947-1, IEC 60947-5-1, EN 60947-5-1, EN 60947 5-2, EN 60947-5-3
(in connection with safety module), EN ISO 14119, EN ISO 12100, EN ISO 13849-1, EN ISO 13849-2, IEC 60204-1, EN 60204-1, IEC 60529, EN 60529, ISO 20653,
UL 508, CSA 22.2 No.14 .
Approvals:
UL 508, CSA 22.2 No.14 , EN ISO 13849-1, EN 60947-5-3, EN 50178, EN 61508-1,
EN 61508-2, EN 61508-4, IEC 62061, EN 60947-1.
Actuation data
Assured operating distance Sao 5 mm with actuator SM A01N
Assured release distance Sar 15 mm with actuator SM A01N
Repeat accuracy ≤ 10%
Switching frequency up to 150 Hz
Distance between two sensors Min. 50 mm
Electrical data
Rated operating voltage Ue: 24 Vac/dc
Rated operating current Ie: 0.25 A (resistive load)
Rated insulation voltage Ui: 120 Vac (with cable)
60 Vac / 75 Vdc (with M8 connector)
120 Vac (with M12 connector, 4-pole) 30 Vac / 36 Vdc (with M12 connector, 8-pole)
Rated impulse withstand voltage (Uimp): 6 kV
1.5 kV (with connector)
Thermal current Ith: 0.25 A
Maximum switching load: 6 W (resistive load)
Protection fuse: 0.25 A type F
Electrical endurance: 1 million operating cycles
Connection with safety modules for safety applications:
Connection with safety modules CS AR-01••••; CS AR-02••••; CS AR-04••••; CS AR-05••••; CS AR-06••••; CS AR-08••••; CS AR-46•024; CS AR-91••••; CS AT-0•••••; CS AT-1•••••; CS AT-3•••••; CS FS-5•••••; CS MF•••••-••; CS MP•••••-••. When connected to the safety module, the sensor can be classified as a control circuit device up to PDF-M (EN 60947-5-3). The system can be used in safety circuits up to PL e/SIL 3/category 4 in accordance with EN ISO 13849-1.
Features approved by UL
Utilization categories: 24 Vdc, 0.25 A (resistive load). Housing features type 1, 4X “indoor use only”, 12. Accessory for CS series.
In compliance with standard: UL 508, CSA 22.2 No.14
Features approved by TÜV SÜD
Supply voltage: 24 Vac/dc
Rated operating current (max.): 0.25 A Ambient temperature: -25°C … +80°C Protection degree: IP67
PL, category: PL e, category 4 with CS AR-08
In compliance with standards: 2006/42/EEC Machine Directive, EN ISO 13849-1:2008, EN 60947-5-3/A1:2005, EN 50178:1997,
EN 61508-1:1998 (SIL 1-3), EN 61508-2:2000 (SIL 1-3), EN 61508-4:1998
(SIL 1-3), IEC 62061:2005 (SIL CL 3), EN 60947-1